Glow-worm Short Cycling / Oversized Boiler or Poor Control

Boiler frequently short cycles (turns on and off rapidly) during heating

Advertisements

Possible Causes

Boiler output too high for system, Incorrect control settings, Blocked or undersized bypass, Poor system balancing

How to Fix / Troubleshooting

Safety: No immediate safety risk, but short cycling reduces efficiency and component life.

  • Check room thermostat location: Ensure it is not near a heat source or in a draught, which can cause rapid on/off cycling.
  • Open more radiators: Ensure enough radiators are open to absorb the boiler's minimum output.
  • Check bypass: If a bypass valve is fitted, ensure it is not fully closed.
  • Engineer tasks:
    • Adjust boiler maximum CH output via settings if supported.
    • Balance radiators to improve heat distribution.
    • Install or adjust an automatic bypass valve if required.

Optimising controls and balancing can significantly improve comfort and efficiency.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Automatic Bypass Valve