Glow-worm
Short Cycling / Oversized Boiler or Poor Control
Boiler frequently short cycles (turns on and off rapidly) during heating
Advertisements
Possible Causes
Boiler output too high for system, Incorrect control settings, Blocked or undersized bypass, Poor system balancing
How to Fix / Troubleshooting
Safety: No immediate safety risk, but short cycling reduces efficiency and component life.
- Check room thermostat location: Ensure it is not near a heat source or in a draught, which can cause rapid on/off cycling.
- Open more radiators: Ensure enough radiators are open to absorb the boiler's minimum output.
- Check bypass: If a bypass valve is fitted, ensure it is not fully closed.
- Engineer tasks:
- Adjust boiler maximum CH output via settings if supported.
- Balance radiators to improve heat distribution.
- Install or adjust an automatic bypass valve if required.
Optimising controls and balancing can significantly improve comfort and efficiency.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Automatic Bypass Valve
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements