Glow-worm
Frozen Condensate Discharge
Condensate pipe repeatedly freezing in cold weather, boiler stops working
Advertisements
Possible Causes
Condensate pipe run externally for long distance, Small bore pipe (less than 32mm), Inadequate insulation, Poor fall on pipe
How to Fix / Troubleshooting
Safety: Do not use boiling water on plastic pipes. Take care on icy ground.
- Locate frozen section: Find the external condensate pipe (usually white or grey plastic) and identify any bulges or ice.
- Thaw gently: Pour warm (not boiling) water over the frozen section or use a warm cloth to thaw the ice.
- Reset boiler: Once thawed and condensate can flow, reset the boiler following the manual.
- Engineer tasks:
- Increase pipe size to at least 32mm externally.
- Improve pipe insulation and reduce external run length.
- Adjust pipe fall to ensure good drainage.
Improving condensate pipe installation will reduce recurrence in future cold spells.