F15
Glow-worm
Gas Valve Control Fault
Boiler displays F15, may run pump but not fire burner
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Gas valve coil open/short, Wiring fault between PCB and gas valve, PCB output stage failure, Incorrect gas valve fitted
How to Fix / Troubleshooting
Safety: Turn off power and isolate gas before any work on the gas valve. Only Gas Safe engineers may work on gas components.
- Reset and observe: Reset the boiler and listen for fan operation. If the fan runs but there is no ignition attempt and F15 appears, the gas valve may not be energised.
- Engineer tasks:
- Measure gas valve coil resistance and compare to specification.
- Check the wiring harness from PCB to gas valve for continuity and secure connections.
- Verify the PCB is sending the correct voltage to the gas valve on ignition demand.
- Replace the gas valve or PCB as indicated by tests.
Do not attempt to adjust or replace the gas valve yourself; incorrect setup can be dangerous.
Advertisements
Repair Difficulty
Professional Required
5/5