F15
Glow-worm Gas Valve Control Fault

Boiler displays F15, may run pump but not fire burner

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Gas valve coil open/short, Wiring fault between PCB and gas valve, PCB output stage failure, Incorrect gas valve fitted

How to Fix / Troubleshooting

Safety: Turn off power and isolate gas before any work on the gas valve. Only Gas Safe engineers may work on gas components.

  • Reset and observe: Reset the boiler and listen for fan operation. If the fan runs but there is no ignition attempt and F15 appears, the gas valve may not be energised.
  • Engineer tasks:
    • Measure gas valve coil resistance and compare to specification.
    • Check the wiring harness from PCB to gas valve for continuity and secure connections.
    • Verify the PCB is sending the correct voltage to the gas valve on ignition demand.
    • Replace the gas valve or PCB as indicated by tests.

Do not attempt to adjust or replace the gas valve yourself; incorrect setup can be dangerous.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Gas Valve
Check Price on Amazon

We may earn a commission from links on this page.