F27
Glow-worm Flame Detection Error / False Flame Signal

Boiler displays F27, ignition aborted, may occur with incorrect gas type or contamination

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Moisture or contamination on electrode, Electrical noise or interference, Incorrect earthing, PCB flame circuit fault

How to Fix / Troubleshooting

Safety: Isolate power and gas before internal inspection.

  • Power reset: Turn off power for several minutes, then restore. If F27 persists, internal checks are needed.
  • Engineer tasks:
    • Inspect and clean the ignition/ionisation electrode and ceramic insulator.
    • Check earth bonding and wiring layout to minimise interference.
    • Verify correct gas type and injector for the installation.
    • Test PCB flame detection circuitry and replace PCB if necessary.

False flame detection must be resolved to ensure safe ignition control.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main PCB