Glow-worm Partial Circulation / Balancing or Sludge Issue

Radiators upstairs get hot but downstairs remain cold

Advertisements

Possible Causes

Sludge build-up in lower circuit, Pump not powerful enough or on low speed, Incorrect system balancing, Air trapped in downstairs pipework

How to Fix / Troubleshooting

Safety: Allow system to cool before bleeding radiators. Use cloths to catch any water.

  • Bleed downstairs radiators: Air can accumulate in lower radiators if system layout is unusual. Bleed each radiator until water flows steadily.
  • Check TRVs: Ensure all downstairs TRVs are fully open and not stuck.
  • Balance system: Slightly close lockshield valves on very hot upstairs radiators to encourage more flow downstairs.
  • Engineer tasks:
    • Assess pump sizing and speed.
    • Powerflush the system if sludge is suspected.

Balancing can significantly improve heat distribution without major work.