Airlock
Grant
Airlock in Primary Heating Circuit
Boiler fires but quickly overheats or shuts down; radiators remain cold at top, pump noisy with rushing water sounds.
Advertisements
Possible Causes
Recent draining/refilling of system, Faulty or closed automatic air vent, Incorrect system filling procedure, Pump installed incorrectly or running too fast
How to Fix / Troubleshooting
Safety: Allow hot components to cool before bleeding. Protect surrounding areas from water spills.
User actions:
- Bleed radiators starting from the lowest to highest points using a radiator key until water flows steadily.
- Monitor and maintain system pressure via the filling loop while bleeding.
Engineer actions:
- Check the automatic air vent near the Grant boiler and pump; ensure the cap is loose (open) and vent is not blocked.
- Manually vent high points in the pipework and the pump housing if it has a bleed screw.
- Verify correct pump orientation and speed setting to ensure adequate circulation.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Automatic air vent
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements