Condensate Fault
Grant Condensate Drain Blockage or Freeze

Boiler locks out during cold weather, gurgling noises, condensate pipe outside is frozen or blocked.

Advertisements

Possible Causes

Frozen external condensate pipe, Blocked condensate trap, Incorrectly sized or uninsulated condensate run, Sagging pipe causing standing water

How to Fix / Troubleshooting

Safety: Take care with hot water and slippery surfaces when thawing pipes. Isolate power to the boiler before working on condensate components.

User steps (frozen pipe):

  • Locate the white plastic condensate pipe exiting the Grant boiler and running outside.
  • If frozen, pour warm (not boiling) water along the external section or wrap it with warm towels until thawed.
  • Once thawed, reset the boiler and check operation.

Engineer steps (blockage/design):

  • Remove and clean the condensate trap inside the boiler, clearing any sludge or debris.
  • Check the fall and support of the condensate pipe to ensure continuous gradient with no low spots.
  • Insulate or increase the diameter of the external condensate pipe in line with Grant and local regulations to reduce freezing risk.