Power Supply Fault
Grant Local Power or Fuse Failure

Boiler display is blank, no lights or response, but other electrical circuits in the property work.

Advertisements

Possible Causes

Blown 3A fuse in fused spur, Tripped MCB for boiler circuit, Loose live/neutral connection at boiler, Internal fuse on PCB blown

How to Fix / Troubleshooting

Safety: Only check fuses if you are competent. Always isolate at the consumer unit if in doubt.

User checks:

  • Check the fused spur supplying the Grant boiler; replace the fuse with the correct rating (usually 3A) if blown.
  • Ensure the spur switch is ON and any neon indicator is lit.
  • Check the consumer unit for a tripped MCB or RCD and reset if appropriate.

Engineer checks:

  • Verify 230 V at the boiler terminals.
  • Inspect and tighten terminal connections inside the boiler.
  • Check any internal PCB fuses and replace with identical type and rating if blown, after identifying the cause.