Hoval Short Cycling / Control Mismatch

Boiler cycles on and off frequently with short run times, rooms do not reach set temperature comfortably

Advertisements

Possible Causes

Boiler oversized for system, Incorrect heating curve on Hoval weather-compensated controller, Room thermostat poorly located, Minimum run time not configured

How to Fix / Troubleshooting

Safety: Control adjustments do not usually require opening the boiler, but always follow the user manual.

  • Thermostat location: Ensure the room thermostat or Hoval room unit is not near heat sources, direct sunlight, or draughts. Relocate if necessary.
  • Adjust heating curve: On weather-compensated Hoval systems, lower the heating curve slightly so the boiler runs longer at lower output.
  • Increase hysteresis: If available, increase the temperature differential on the room thermostat to reduce rapid cycling.
  • If cycling remains excessive, a heating engineer may need to add system volume (buffer tank) or adjust boiler parameters.