A08
Hoval
Safety Chain Interruption (Limit or Flow Switch Open)
Boiler displays A08, no heating or hot water, fan may run but burner does not ignite
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open safety thermostat, Flow switch not proving, Faulty wiring in safety loop, Faulty control PCB input
How to Fix / Troubleshooting
Safety: Do not bridge or bypass any safety devices. Identify and correct the root cause.
- Check system pressure and flow: Low water pressure or closed valves can prevent the flow switch from closing. Ensure all isolation valves on the Hoval boiler flow and return are open and system pressure is adequate.
- Inspect flow switch: On models with a mechanical flow switch, check for stuck paddle or debris. Gently tap the housing to free a stuck switch, but if it sticks again, it must be cleaned or replaced.
- Safety thermostat chain: Trace the safety thermostat wiring (overheat, flue stat if fitted) for loose connectors or damaged cables.
- If A08 persists, a technician should test continuity through the safety chain and verify the control PCB input.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Flow Switch / Safety Thermostat Chain
Check Price on Amazon