A10
Hoval
Low Water Pressure / Water Shortage
Boiler displays A10, no burner operation, may indicate low water pressure or flow
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
System pressure below minimum, Leak in heating circuit, Faulty pressure sensor, Air in boiler causing false low pressure reading
How to Fix / Troubleshooting
Safety: Do not overfill the system. Check for leaks before topping up repeatedly.
- Read pressure: Check the pressure gauge or digital reading on the Hoval boiler. If below the minimum (often 0.8–1.0 bar), top up using the filling loop until within the recommended range.
- Bleed air: After topping up, bleed radiators and the boiler's automatic air vent (if accessible), then recheck pressure.
- Check for leaks: Inspect visible pipework, radiator valves, and the boiler underside for signs of water. Persistent pressure loss indicates a leak that must be repaired.
- Pressure sensor: If pressure is correct but A10 remains, the water pressure sensor may be blocked or faulty. A technician can remove and clean or replace the sensor.