C9
Ideal
DHW Temperature Sensor Out of Range
Ideal boiler displays C9 and may not provide stable hot water
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty DHW NTC thermistor, Poor contact with plate heat exchanger, Damaged cable, PCB fault
How to Fix / Troubleshooting
Safety first: Hot water components can be very hot. Internal work is for engineers only.
User steps:
- Reset: Power cycle and reset once.
- Check flow: Ensure adequate hot water flow at taps; very low flow can cause temperature swings.
If C9 persists, an engineer should test and replace the DHW NTC sensor and check wiring and PCB.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
DHW NTC Thermistor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements