F5
Ideal Flame Detection Fault / Flame Signal Error

Ideal boiler displays F5 and locks out, often accompanied by loud ignition or poor burning

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Contaminated flame sensor, Poor earth connection, Incorrect combustion (air/gas ratio), Faulty PCB flame detection circuit

How to Fix / Troubleshooting

Safety first: Flame detection and combustion issues are safety critical. Only a Gas Safe registered engineer should adjust combustion or access the burner.

User checks:

  • Reset once: Turn the boiler off and on, then press reset. Observe if the boiler runs normally or quickly returns to F5.
  • Check for signs of poor combustion: Yellow, sooty flames visible through a viewing window (if present), or soot around the flue terminal, indicate a serious issue. Turn the boiler off and call an engineer immediately.

Engineer actions (for information):

  • Clean or replace the flame sensor (ionisation electrode).
  • Check earth continuity and wiring to the electrode.
  • Perform combustion analysis and adjust or replace the gas valve if required.
  • Test PCB flame detection circuitry.

Do not continue to reset the boiler if F5 recurs. Arrange professional service.