02
Immergas
Flame Loss During Operation
Boiler displays error 02 and locks out shortly after ignition attempt, flame appears briefly then goes out.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Unstable gas pressure, Blocked or partially blocked burner, Faulty ionisation electrode or wiring, Faulty gas valve modulation coil
How to Fix / Troubleshooting
Safety warning: Work on gas and combustion components must be carried out by a qualified technician. Isolate power and gas before opening the boiler casing.
- Check gas supply stability: Confirm that other gas appliances do not fluctuate or go out. If they do, contact the gas supplier.
- Inspect burner: Remove the burner assembly as per Immergas service instructions. Check for rust, debris, or soot blocking the burner ports. Clean with a soft brush and vacuum; do not enlarge the ports.
- Check ionisation electrode: Ensure the electrode is correctly positioned in the flame, clean, and free from cracks. Verify the cable is not damaged and is firmly connected to the PCB.
- Verify gas valve modulation (engineer only): Using a manometer, check that the gas valve maintains correct burner pressure during operation. If pressure drops or the valve cuts out, replace the gas valve.
- Check flue and air intake: Ensure the flue terminal is not blocked by leaves, ice, or debris, and that the concentric flue is correctly fitted. Poor combustion air can cause flame instability.
- Test operation: After reassembly, run the boiler at maximum and minimum power to ensure the flame remains stable and error 02 does not reoccur.