06
Immergas
Control Board / Internal Electronics Fault
Boiler displays error 06, no ignition, often after a power surge or wiring disturbance.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Damaged main PCB, Loose low-voltage connections, Incorrect polarity or missing earth, Surge damage from mains supply
How to Fix / Troubleshooting
Safety: Isolate the boiler from the mains before accessing the control board. Only qualified personnel should replace electronic control boards.
- Power cycle: Turn off the boiler at the isolator for 2–3 minutes, then restore power to clear transient faults.
- Check supply polarity and earth: Verify that live, neutral, and earth are correctly connected and secure at the boiler terminal block. Incorrect polarity can cause control faults.
- Inspect PCB connections: Remove the front cover and check all multi-pin connectors on the PCB for secure fit and signs of overheating or moisture ingress.
- Look for visible PCB damage: Burn marks, swollen components, or corrosion indicate board failure. In such cases, replace the PCB with the exact Immergas part number.
- Surge protection: If the fault followed a storm or power surge, consider installing an external surge protector to protect the new board.
- Commissioning: After PCB replacement, configure boiler parameters (if required) according to the Immergas service manual and test all functions.