37
Immergas Fan Speed / Air Pressure Regulation Fault

Boiler displays error 37, often related to fan speed or air pressure anomalies.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Fan running outside expected speed range, Blocked venturi or pressure tubes, Faulty air pressure switch or sensor, PCB fan control fault

How to Fix / Troubleshooting

Safety: Isolate power before accessing the fan and pressure components.

  • Clean venturi and tubes: Remove and clean the venturi and silicone tubes connecting to the air pressure switch or sensor. Ensure they are dry and free of condensate.
  • Check fan blades: Inspect the fan impeller for dirt build-up that could affect speed. Clean carefully without bending blades.
  • Test pressure switch/sensor: Verify that the switch changes state or that the sensor output is within specification when the fan runs. Replace if faulty.
  • PCB diagnosis: If the fan and pressure components are good but error 37 persists, the PCB may not be correctly controlling or reading fan speed and may need replacement.
  • Re-test: After repair, run the boiler and confirm stable fan operation without error 37.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Air Pressure Switch
Check Price on Amazon

We may earn a commission from links on this page.