A03
Immergas Low System Pressure Lockout

Boiler displays A03, water pressure too low, boiler will not start.

Advertisements

Possible Causes

Loss of water from system, Leak in radiators or pipework, Faulty pressure sensor, User has not topped up system

How to Fix / Troubleshooting

Safety: Do not overfill the system. Typical cold pressure is around 1.0–1.5 bar; check your Immergas manual.

  • Top up pressure: Locate the filling loop under the boiler. Open the valves slowly until the pressure gauge reaches the recommended value, then close both valves.
  • Bleed air: Bleed radiators and re-check pressure, topping up again if needed.
  • Check for leaks: Inspect radiators, valves, and visible pipework for signs of water. Repair leaks promptly.
  • Sensor check: If the gauge shows correct pressure but A03 persists, the pressure sensor may be faulty and should be replaced by a technician.