11
Intergas
Return Temperature Sensor (CH Return NTC) Fault
Boiler displays error code 11, boiler locks out, no heating or hot water
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open circuit CH return NTC sensor, Shorted CH return NTC sensor, Loose NTC connector on PCB, Faulty main PCB
How to Fix / Troubleshooting
Warning: Internal sensor and PCB checks must be carried out by a competent engineer. Do not remove the boiler cover.
- Attempt a reset: Use the reset function on the boiler control panel. If the error returns, the sensor circuit is likely defective.
- Check system pressure and flow: Low pressure or no circulation can cause abnormal temperature readings. Ensure pressure is 1.0–1.5 bar and that radiators heat evenly when the boiler runs (if it will run).
- Engineer diagnosis: A technician will measure the CH return NTC resistance, inspect the wiring harness, reseat connectors, and replace the return NTC sensor or PCB as required.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
CH Return NTC Sensor
Check Price on Amazon