13
Intergas
Cold Water Inlet Sensor / Flow Sensor Temperature Fault
Boiler displays error code 13, intermittent hot water temperature spikes or shutdown
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty cold inlet NTC (if fitted), Faulty DHW flow sensor assembly, Wiring fault between sensor and PCB, PCB input failure
How to Fix / Troubleshooting
Warning: This involves internal sensors on the DHW circuit. Only a qualified engineer should access them.
- Confirm symptom: Note whether the error occurs only on hot water demand or also during heating. This helps the engineer identify which sensor is affected.
- Check inlet filters and strainers: Ensure good cold water flow to the boiler. Clean any external strainers or filters on the cold inlet (if accessible) after isolating water supply.
- Reset boiler: Reset and test again. If code 13 recurs, do not continue to cycle power repeatedly; call an engineer.
- Engineer tasks: The engineer will test the relevant NTC or flow sensor, check wiring continuity, and replace the DHW flow sensor or cold inlet NTC as required.