25
Intergas
Overheat Protection / High Limit Trip
Boiler displays error code 25, boiler overheats and shuts down
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed pump or no circulation, Blocked plate heat exchanger, Closed valves or blocked filters, Faulty overheat thermostat or NTC
How to Fix / Troubleshooting
Warning: Overheating can damage the boiler and system. Parts of the system may be very hot. Allow the boiler to cool before touching any pipework.
- Check system pressure: Ensure pressure is 1.0–1.5 bar. Low pressure can cause poor circulation and overheating. Top up if needed.
- Check radiator valves: Make sure at least some radiators are open. If all TRVs are closed, the boiler cannot dissipate heat.
- Listen for pump operation: When the boiler tries to run, you should hear the pump. If it is silent or very noisy, the pump may be seized or airlocked.
- Bleed pump (engineer task on most models): Many Intergas pumps are internal; bleeding should be done by an engineer.
- Engineer actions: The engineer will check pump operation, clean or replace the plate heat exchanger, verify filters and strainers are clear, and test the overheat thermostat and NTC sensors.