Boiler condensate pipe repeatedly freezes in cold weather
Advertisements
Possible Causes
Undersized external condensate pipe, Excessive pipe run outside, Lack of insulation, Inadequate fall on pipe
How to Fix / Troubleshooting
Safety: Do not pour boiling water on plastic pipes. Turn off boiler if condensate backs up and causes gurgling or leaks.
Steps:
- Thaw the external condensate pipe gently with warm water or a hot water bottle.
- Insulate the external section with weatherproof lagging.
- Where possible, reroute the pipe internally or increase its diameter to at least 32 mm as per best practice.
- Ensure the pipe has a continuous fall to the drain to prevent standing water.