Expansion Vessel Failure / Overpressure
Boiler pressure rises rapidly when heating is on and discharges water from the safety valve
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Flat or ruptured expansion vessel diaphragm, Incorrect pre-charge pressure, Blocked connection between vessel and system, Faulty pressure relief valve
How to Fix / Troubleshooting
Safety: Hot water may discharge from the safety pipe. Keep clear of the discharge outlet. Allow system to cool before working on it.
Steps:
- Note the cold pressure (system off) and the hot pressure (system on). A large increase suggests expansion vessel issues.
- A technician should isolate and check the expansion vessel pre-charge with a tyre gauge, recharging with air/nitrogen to the value specified by IVT (typically around 0.8–1.0 bar).
- If the vessel will not hold pressure, replace the expansion vessel.
- After repeated discharges, the pressure relief valve may not reseal properly and should be replaced.