A05
IVT Primary Circuit Overheat / Safety Thermostat Trip

Boiler locks out with A05, overheating, may make boiling or kettling noises before shutdown

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked primary heat exchanger, Failed or seized circulation pump, Airlock in primary circuit, Faulty overheat thermostat or NTC sensor

How to Fix / Troubleshooting

Safety: Overheating can cause scalding and damage. Turn off power and allow the boiler to cool completely before touching any components.

User actions:

  • Check that all radiator valves are open to allow circulation.
  • Ensure that system pressure is within the correct range (usually 1.0–1.5 bar cold).
  • Perform a single reset once the boiler is cool. If A05 returns, call a technician.

Technician actions:

  • Verify operation of the circulation pump (check for voltage, rotation, and free movement). Replace the pump if seized or weak.
  • Bleed air from the pump and high points in the system.
  • Check the primary heat exchanger for scale or sludge blockage; power-flush or replace if necessary.
  • Test the overheat thermostat and flow NTC sensor for correct resistance and replace if faulty.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Circulation Pump
Check Price on Amazon