A06
IVT Air Pressure Switch / Fan Proving Fault

Boiler shows A06, fan runs but ignition sequence does not start

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked flue or air intake, Faulty air pressure switch, Damaged or blocked pressure tubing, Fan not reaching required speed

How to Fix / Troubleshooting

Safety: Turn off power before removing the boiler case. Flue and combustion checks must be done by a qualified engineer.

Homeowner checks:

  • Inspect the flue terminal outside for obstructions and remove any debris.

Technician checks:

  • Inspect and clean the air pressure switch tubes for splits, kinks, or blockages; replace tubing if degraded.
  • Test the air pressure switch with a manometer or continuity tester to confirm switching at the correct pressure.
  • Verify that the fan reaches the commanded speed and that the PCB receives the correct feedback signal.
  • Check the flue system for restrictions or incorrect installation.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Air Pressure Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements