A07
IVT
Flow Temperature Sensor Fault (NTC Open/Short)
Boiler displays A07, no heating or hot water, pump may run continuously
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty flow NTC sensor, Damaged sensor wiring or connector, Water ingress into sensor harness, PCB input fault
How to Fix / Troubleshooting
Safety: Isolate power before accessing internal components. Allow boiler to cool.
Steps for technician:
- Locate the flow temperature NTC sensor on the primary flow pipe inside the IVT boiler.
- Inspect the connector and wiring for corrosion, loose pins, or damage. Clean and reseat the connector.
- Measure the resistance of the NTC at a known water temperature and compare with IVT resistance tables.
- If readings are out of range or intermittent, replace the flow NTC sensor.
- If the sensor is correct, test the PCB sensor input; replace the control board if confirmed faulty.
Homeowners should not attempt to replace sensors unless competent and allowed by local regulations.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Flow Temperature NTC Sensor