A07
IVT Flow Temperature Sensor Fault (NTC Open/Short)

Boiler displays A07, no heating or hot water, pump may run continuously

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty flow NTC sensor, Damaged sensor wiring or connector, Water ingress into sensor harness, PCB input fault

How to Fix / Troubleshooting

Safety: Isolate power before accessing internal components. Allow boiler to cool.

Steps for technician:

  • Locate the flow temperature NTC sensor on the primary flow pipe inside the IVT boiler.
  • Inspect the connector and wiring for corrosion, loose pins, or damage. Clean and reseat the connector.
  • Measure the resistance of the NTC at a known water temperature and compare with IVT resistance tables.
  • If readings are out of range or intermittent, replace the flow NTC sensor.
  • If the sensor is correct, test the PCB sensor input; replace the control board if confirmed faulty.

Homeowners should not attempt to replace sensors unless competent and allowed by local regulations.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Flow Temperature NTC Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements