A10
IVT
Water Pressure Sensor Electrical Fault
Boiler shows A10, will not start, pressure reading on display is unrealistic or fixed
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective electronic pressure sensor, Blocked sensor port, Damaged wiring harness, PCB analogue input failure
How to Fix / Troubleshooting
Safety: Allow boiler to cool and isolate power. Close isolation valves if removing the sensor.
Technician actions:
- Compare the displayed pressure with the mechanical gauge (if fitted). If they differ significantly, suspect the sensor.
- Inspect the pressure sensor body on the hydraulic block for leaks or corrosion.
- Remove and check the sensor port for sludge or debris; clean carefully.
- Test the sensor output voltage versus actual pressure according to IVT service data.
- Replace the water pressure sensor if faulty; if readings remain incorrect, test/replace the PCB.