A13
IVT
Flow Rate / Delta-T Regulation Fault
Boiler displays A13, burner shuts down and restarts frequently (short cycling)
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Insufficient system flow, Stuck or undersized bypass valve, Pump speed incorrectly set, Blocked system filter
How to Fix / Troubleshooting
Safety: Allow system to cool before adjusting valves or filters.
Steps:
- Ensure all radiator valves and zone valves are open to provide adequate flow.
- Check that the automatic bypass valve (if fitted externally) is correctly adjusted and not fully closed.
- Clean the system filter or magnetic filter on the return line.
- Adjust the pump speed on the IVT boiler (if variable) to a higher setting to improve circulation.
- If A13 persists, a technician should check pipe sizing, balancing, and delta-T across the boiler and system.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Automatic Bypass Valve
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements