A14
IVT
DHW Flow Switch / Flow Sensor Fault
Boiler shows A14, no hot water, heating may still work
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck DHW flow switch, Blocked DHW inlet filter, Faulty DHW flow sensor (turbine), Wiring fault between sensor and PCB
How to Fix / Troubleshooting
Safety: Isolate power and close cold water inlet before removing any DHW components.
Steps:
- Check that the cold water isolation valve to the boiler is fully open.
- Clean the DHW inlet filter/strainer if accessible.
- A technician should remove and inspect the DHW flow switch or turbine sensor for debris or limescale; clean or replace as needed.
- Verify the electrical connection from the flow sensor to the PCB.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
DHW Flow Sensor