A15
IVT Gas Valve Control / Internal Gas Valve Fault

Boiler displays A15, burner does not start, gas supply appears normal

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective gas valve coil, Stuck gas valve mechanism, No control signal from PCB, Incorrect wiring to gas valve

How to Fix / Troubleshooting

Critical safety: Only a Gas Safe / certified technician may work on gas valves. Do not attempt DIY repairs.

Technician procedure:

  • Confirm mains gas supply and inlet pressure to the boiler.
  • Measure voltage at the gas valve coil(s) during ignition attempt.
  • If voltage is present but no gas flow, replace the gas valve assembly with an IVT-approved part.
  • If no voltage, test the PCB gas valve driver and safety interlocks (air pressure switch, overheat, etc.).