Keston
Frozen or Restricted Condensate Discharge
Boiler locks out more often in very cold weather, with visible condensate issues
Advertisements
Possible Causes
Undersized external condensate pipe, Poor insulation, Long external run, Blocked condensate trap
How to Fix / Troubleshooting
Safety: Take care when working outside in icy conditions. Surfaces may be slippery.
User actions:
- Inspect the external condensate pipe for ice build-up. Thaw gently using warm (not boiling) water or warm cloths.
- Once thawed, reset the boiler and observe operation.
- If the pipe repeatedly freezes, arrange for a permanent upgrade.
Engineer actions:
- Increase condensate pipe diameter and improve insulation in accordance with Keston and regulatory guidance.
- Reduce external pipe length where possible and reroute internally if feasible.
- Clean the condensate trap and check for correct fall to the drain.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Condensate Pipework
Check Price on Amazon