Short Cycling / Oversized Boiler or Control Issue
Boiler short cycles, frequently turning on and off with little heat delivered
Advertisements
Possible Causes
Boiler output too high for system, Incorrect control settings, TRVs closing too quickly, No bypass or low system volume
How to Fix / Troubleshooting
Safety: Short cycling reduces efficiency and can shorten component life but is not usually an immediate safety risk.
User actions:
- Ensure at least a few radiators are fully open to provide adequate load.
- Increase room thermostat setpoint slightly to reduce rapid on/off behaviour.
Engineer actions:
- Adjust the Keston boiler maximum CH output and flow temperature to better match the system.
- Verify that an automatic bypass valve is fitted and correctly set.
- Review control strategy (e.g., weather compensation, room thermostat location) and optimise.
- Consider adding a buffer vessel or additional radiators if the system volume is very small.