Possible Causes

Weak ignition spark, Incorrect gas pressure, Partially blocked burner, Faulty flame sensor

How to Fix / Troubleshooting

Safety: Repeated failed ignition attempts can release unburnt gas. Do not keep resetting the boiler.

User actions:

  • Attempt only one reset. If the boiler fails again, switch it off and call an engineer.
  • Confirm that other gas appliances work normally to rule out a general gas supply issue.

Engineer actions:

  • Inspect and clean the Keston burner and combustion chamber, removing any debris or corrosion.
  • Check ignition electrode gap and condition; replace electrode and lead if worn.
  • Measure gas inlet and burner pressures and adjust or replace the gas valve as required.
  • Test flame sensor operation and replace if rectification current is low.