E03
Keston
Primary Overheat / High Limit Trip
Boiler shows E03 and shuts down shortly after starting, primary flow temperature rises rapidly
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed pump, Blocked plate heat exchanger, Airlock in primary circuit, Faulty overheat thermostat or NTC sensor
How to Fix / Troubleshooting
Safety: Allow the boiler to cool fully before touching any pipework. Isolate electrical power before removing covers.
User checks:
- Check system pressure is at least 1.0 bar when cold; top up via filling loop if low.
- Bleed air from radiators and any accessible manual air vents.
- Ensure all radiator valves and isolation valves near the boiler are open.
Engineer checks:
- Confirm the Keston circulation pump is running when there is a heat demand. Listen for operation and check for vibration; test for 230 V supply at the pump terminals.
- Inspect and clean the primary side of the Keston plate heat exchanger if blocked with sludge or scale; powerflush system if contamination is severe.
- Check for closed valves or blocked strainers on the flow/return pipework.
- Test the primary NTC sensor and overheat thermostat for correct resistance values and continuity; replace if out of specification.
- Verify correct pump speed setting and that bypass (if fitted) is adjusted correctly to maintain flow.