E12
Keston
External Control / Thermostat Circuit Fault
Boiler displays E12, no response to thermostat or programmer, boiler may stay off
Advertisements
Possible Causes
Open circuit room thermostat, Faulty wiring to external controls, Incorrect link on boiler control terminals, Faulty timeclock
How to Fix / Troubleshooting
Safety: Isolate power before accessing the wiring centre or boiler terminal strip.
User checks:
- Ensure the room thermostat or wireless controller is turned up and calling for heat.
- Check that any external programmer is set to an ON period and not in holiday or OFF mode.
Engineer checks:
- At the Keston boiler control terminals, verify that the required link (if no external controls are used) is fitted between the correct terminals as per the installation manual.
- Test continuity of the room thermostat circuit and any wiring centre connections; repair loose or broken wires.
- Bypass the external controls temporarily at the boiler terminals to confirm the boiler responds; if it does, replace or repair the external control device.
- Check for correct voltage presence on control inputs as specified by Keston.
Advertisements
Repair Difficulty
Easy
2/5