E13
Keston
Gas Valve Control Fault
Boiler shows E13, fan runs but ignition sequence does not start
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Gas valve coil failure, Loose gas valve connector, PCB output fault, Incorrect gas valve setting
How to Fix / Troubleshooting
Safety: All gas valve work must be carried out by a Gas Safe registered engineer. Isolate gas and power before starting.
User checks:
- Confirm gas supply to the property is available and other gas appliances operate normally.
- Do not attempt to adjust or tap the gas valve.
Engineer checks:
- Check the electrical connector on the Keston gas valve for secure fit and no signs of overheating.
- Measure resistance of the gas valve coil(s) and compare with manufacturer specifications; replace the valve if open or shorted.
- During ignition attempt, measure control voltage at the gas valve terminals; if absent, suspect PCB fault.
- After replacement, commission the boiler with a flue gas analyser and adjust gas valve settings as per Keston combustion instructions.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Gas Valve Assembly