E17
Keston
Fan Speed / Tachometer Fault
Boiler shows E17, fan speed appears abnormal or noisy
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty fan speed sensor, Fan bearings worn, PCB fan control fault, Obstructed fan impeller
How to Fix / Troubleshooting
Safety: Isolate power and gas. Do not run the boiler with a noisy or failing fan.
User checks:
- Listen for unusual grinding or whirring noises from the boiler when it attempts to start. Report these to the engineer.
Engineer checks:
- Inspect the Keston fan assembly for free rotation and absence of play in the bearings; replace if noisy or stiff.
- Check the fan tachometer/speed feedback wiring to the PCB for damage or loose connectors.
- Monitor fan speed via diagnostic mode (if available) and compare with target values.
- If the fan is mechanically sound but speed control is erratic, suspect and test the main PCB.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Flue Fan Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements