E18
Keston Diverter Valve Position Fault

Boiler intermittently shows E18, particularly when switching between heating and hot water

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Sticking diverter valve, Faulty diverter motor/actuator, Sludge in valve body, Position microswitch failure

How to Fix / Troubleshooting

Safety: Isolate power and allow the boiler to cool before working on the hydraulic components.

User checks:

  • Note whether the fault occurs when using hot water, heating, or both, and inform the engineer.

Engineer checks:

  • Locate the Keston diverter valve assembly and check the actuator for correct movement during changeover between DHW and CH.
  • Remove the actuator head and manually exercise the valve spindle; if stiff, clean or replace the valve body.
  • Test any position microswitches or feedback sensors for correct operation.
  • Flush the system and fit a magnetic filter if sludge is present to prevent recurrence.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Diverter Valve Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements