E21
Keston
Internal Communication / PCB Sensor Bus Fault
Boiler shows E21, display may indicate sensor mismatch or internal communication error
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty main PCB, Loose internal harness connections, Damaged sensor bus wiring, Electrical interference
How to Fix / Troubleshooting
Safety: Isolate power before accessing internal electronics. Avoid static discharge to PCB components.
User checks:
- Attempt a single reset. If E21 returns, professional service is required.
Engineer checks:
- Inspect all low-voltage harness connections between sensors and the Keston main PCB; reseat and secure connectors.
- Check for signs of water ingress or corrosion on the PCB and connectors.
- Verify correct earthing and that no high-voltage cables are routed alongside sensor wiring causing interference.
- If wiring and sensors test correctly, replace the main PCB following Keston procedures and reconfigure as required.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control PCB
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements