E25
Keston
Low Flow / Minimum Flow Rate Fault
Boiler shows E25, CH flow temperature rises too quickly at low load
Advertisements
Possible Causes
All TRVs closed, Bypass not fitted or set, Pump speed too low, Blocked system filter
How to Fix / Troubleshooting
Safety: Surfaces may be hot. Allow system to cool before adjusting valves.
User checks:
- Ensure at least a few radiators have their thermostatic radiator valves (TRVs) fully open.
- Check that any manual bypass radiator (usually in the hall or bathroom) is open.
Engineer checks:
- Verify that a suitable automatic bypass valve is installed and correctly set for the Keston boiler.
- Check and clean any system filter or strainer on the return pipework.
- Increase pump speed if set too low, ensuring noise and flow remain acceptable.
- Advise on correct TRV usage to maintain minimum flow through the boiler.