Klimosz
Heating Circuit Isolation / Diverter Stuck in DHW Position
Boiler produces hot water but no central heating.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck three-way valve on Klimosz combi boiler, Heating flow/return valves closed, Faulty room thermostat or wiring, Heating mode disabled in controller
How to Fix / Troubleshooting
Safety: Isolate power before removing boiler covers.
- Check valves: Confirm that the heating flow and return isolation valves under the boiler are fully open.
- Verify controller settings: Ensure heating mode is enabled and the schedule allows heating on the Klimosz controller.
- Test thermostat: Raise the room thermostat setting and listen for a click or check for a call-for-heat symbol on the display.
- Inspect diverter valve: Observe whether the diverter motor moves when switching between DHW and heating. If it remains in DHW position, the valve or actuator may need replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Three-Way Diverter Valve
Check Price on Amazon