Klimosz
DHW Temperature Regulation Problem
Domestic hot water temperature is unstable, alternating between hot and cold.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Scaled plate heat exchanger on Klimosz combi, Faulty DHW NTC sensor, Modulation control issues, Inadequate minimum flow rate through boiler
How to Fix / Troubleshooting
Safety: Risk of scalding. Test water temperature carefully.
- Check flow rate: Ensure the hot tap is opened sufficiently to meet the boiler’s minimum flow requirement (see Klimosz manual).
- Clean or replace plate exchanger: If in a hard water area, remove and descale the plate heat exchanger or replace it.
- Verify DHW sensor: Check the DHW NTC sensor for correct mounting and resistance. Replace if faulty.
- Controller settings: Ensure DHW temperature setpoint is reasonable (e.g., 45–50°C) and not at extremes that cause overshoot.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Plate Heat Exchanger