E06
Klimosz DHW Temperature Sensor (NTC) Fault

Boiler displays E06, domestic hot water (DHW) temperature is incorrect or not regulated.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed DHW NTC sensor in Klimosz storage tank or plate exchanger, Loose or corroded sensor connector, Damaged sensor cable, Control board sensor input fault

How to Fix / Troubleshooting

Safety: Turn off power and close water valves to the boiler if you need to remove any wet components.

  • Locate DHW sensor: On combi Klimosz boilers, the DHW NTC is usually clipped to the plate heat exchanger; on system boilers with cylinder, it may be inserted into a tank pocket.
  • Check connection: Ensure the sensor plug is fully seated on the control board and at the sensor end. Clean any oxidation with contact cleaner.
  • Measure sensor: Disconnect the sensor and measure resistance with a multimeter. Compare with Klimosz NTC chart. Replace if out of specification.
  • Inspect cable routing: Ensure the cable is not pinched between panels or touching hot flue parts which can melt insulation.
  • Test operation: After replacing or reseating the sensor, restore power and run a hot water tap. Confirm that the temperature is stable and E06 does not reappear.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

DHW NTC Temperature Sensor