E12
Klimosz
Flue Gas Temperature Too High
Boiler shows E12, burner stops, sometimes accompanied by unusual fan noise.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked or undersized flue on Klimosz boiler, Sooted heat exchanger, Faulty flue gas temperature sensor, Incorrect burner adjustment causing high flue temps
How to Fix / Troubleshooting
Safety: Risk of flue gas spillage. Turn off the boiler and ventilate the area.
- Inspect flue: Check the entire flue route for blockages, crushed sections, or incorrect slope. Ensure terminal is clear.
- Clean heat exchanger: Remove the burner and access the primary heat exchanger. Brush and vacuum soot and deposits from the fins and passages according to Klimosz service instructions.
- Check flue gas sensor: Locate the flue gas NTC sensor on the flue outlet. Inspect wiring and measure resistance. Replace if out of specification.
- Combustion check: Burner gas/air ratio should be checked and adjusted with a flue gas analyzer by a qualified technician. Do not adjust gas valve without proper equipment.
- Restart: After cleaning and checks, reset the boiler and monitor flue temperature readings if available.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Flue Gas Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.