E13
Klimosz Condensate Drain Blocked

Boiler displays E13, condensate may be visible around the base, burner may not start.

Advertisements

Possible Causes

Blocked condensate trap on Klimosz condensing boiler, Frozen condensate pipe, Kinked or incorrectly sloped condensate hose, Debris in condensate siphon

How to Fix / Troubleshooting

Safety: Condensate is mildly acidic. Wear gloves and eye protection.

  • Inspect condensate pipe: Follow the plastic condensate pipe from the boiler to the drain. Check for kinks, sagging, or external freezing in cold weather.
  • Clean trap: Remove the condensate trap/siphon under the boiler. Empty and rinse with clean water. Remove sludge or debris.
  • Check slope: Ensure the condensate pipe slopes continuously downward to the drain with no upward loops.
  • Defrost if frozen: If the external pipe is frozen, thaw gently with warm (not boiling) water and insulate the pipe afterwards.
  • Reassemble and test: Refit the trap, ensure all seals are tight, then reset the boiler and check for leaks and normal operation.