E15
Klimosz Gas Valve / Gas Supply Fault

Boiler displays E15, no ignition, gas smell may be present if recently serviced.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Closed manual gas cock at Klimosz boiler, Faulty gas valve coil, Loose gas valve wiring, Internal gas valve blockage

How to Fix / Troubleshooting

Safety: If you smell gas, do not operate electrical switches. Ventilate the area and close the main gas valve. Call a gas professional immediately.

  • Check manual gas valve: Ensure the gas cock under the boiler is fully open (handle parallel to the pipe).
  • Inspect wiring: With power off, check the gas valve connectors for secure fit and no corrosion.
  • Measure coil resistance: Use a multimeter to measure the gas valve coil resistance and compare with Klimosz specifications. Replace the valve if open-circuit.
  • Reset boiler: After confirming gas supply and wiring, reset the boiler. If E15 persists, the gas valve or control board output is likely faulty.
  • Professional adjustment: Any gas valve replacement or adjustment must be carried out by a certified Klimosz service technician with combustion analysis.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Gas Valve Assembly