E16
Klimosz
Power Supply / Low Voltage Fault
Boiler shows E16, display may flicker, boiler may reboot randomly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Unstable mains supply, Loose power terminal connections, Internal low-voltage power supply fault on Klimosz PCB, Incorrect earthing
How to Fix / Troubleshooting
Safety: Isolate the boiler from mains before opening the electrical compartment.
- Check mains connections: Verify that live, neutral, and earth wires are firmly secured at the boiler terminal block.
- Measure voltage: Use a multimeter to check mains voltage at the boiler. If significantly outside 230 V ±10%, consult an electrician.
- Inspect PCB for damage: Look for burnt components or bulging capacitors on the power supply section of the Klimosz control board.
- Eliminate external causes: Avoid sharing the boiler circuit with heavy loads (welders, compressors) that cause voltage dips.
- Board replacement: If E16 persists with stable supply, the internal power supply on the PCB may be defective and require replacement by a technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control PCB
Check Price on Amazon