E18
Klimosz Air in System / Flow Sensor Fault

Boiler shows E18, burner stops, sometimes accompanied by gurgling noises.

Advertisements

Possible Causes

Air lock in Klimosz heat exchanger, Faulty flow switch or flow sensor, Insufficient system pressure, Blocked automatic air vent

How to Fix / Troubleshooting

Safety: Allow the boiler to cool before bleeding air.

  • Check pressure: Ensure system pressure is at least 1.0–1.5 bar when cold.
  • Bleed boiler and radiators: Use bleed valves to remove trapped air from high points and the boiler’s automatic air vent. Loosen the cap slightly to ensure it can vent.
  • Inspect flow sensor: On combi models, check the DHW flow sensor or turbine for debris. Clean or replace if stuck.
  • Check pump speed: If the pump has adjustable speed, set it to a higher setting to improve circulation and purge air.
  • Reset and test: After bleeding and cleaning, reset the boiler and observe for stable operation without E18.