E20
Klimosz
Room Thermostat / Communication Fault
Boiler shows E20, burner does not start, room thermostat appears to call for heat.
Advertisements
Possible Causes
Open-circuit room thermostat wiring, Incorrect thermostat settings, Faulty Klimosz room controller, Misconfigured bus communication
How to Fix / Troubleshooting
Safety: Turn off power before modifying control wiring.
- Check thermostat demand: Ensure the room thermostat or Klimosz controller is set above room temperature and in heating mode.
- Inspect wiring: Verify continuity of the thermostat cable between the boiler terminals and the room unit. Tighten all terminal screws.
- Bypass test: Temporarily bridge the thermostat terminals at the boiler (if using simple on/off control). If the boiler starts, the thermostat or its wiring is faulty.
- Bus systems: For eBUS or proprietary Klimosz controllers, check that the correct controller type is selected in the boiler menu and that polarity (if required) is correct.
- Replace controller: If wiring is sound and E20 persists, replace or reprogram the room controller according to Klimosz instructions.