E18
Kospel
External Control Input Fault
Boiler displays E18; external room thermostat or controller not recognized
Advertisements
Possible Causes
Incorrect wiring of room thermostat, Open circuit in control cable, Wrong control mode selected in parameters, Faulty external controller
How to Fix / Troubleshooting
Safety first: Turn off power before working on low-voltage control wiring.
Steps to check:
- Verify wiring diagram: Refer to the Kospel installation manual and confirm that the room thermostat or controller is wired to the correct terminals (e.g., TA, RT, or BUS terminals).
- Check cable continuity: Inspect the cable for damage and test continuity between the boiler and the thermostat.
- Confirm control type: Ensure the boiler parameter settings match the type of controller used (on/off, OpenTherm, proprietary Kospel controller, etc.).
- Bypass test: Temporarily link the thermostat terminals at the boiler to simulate a call for heat. If the boiler responds, the external controller or its cable is faulty.
When to call a technician: If you are unsure about control wiring or parameter settings, consult a heating professional.