Laars Water Hammer / Thermal Expansion Noise

Boiler makes loud banging or knocking noises in the piping when starting or stopping.

Advertisements

Possible Causes

Fast-closing zone valves, Loose piping supports, High flow rates causing sudden pressure changes, Thermal expansion without proper expansion tank or valves

How to Fix / Troubleshooting

Safety first: No immediate combustion hazard, but turn off power if you suspect a leak or structural issue.

  • Identify source: Listen to locate whether the noise comes from the Laars boiler, near zone valves, or along piping.
  • Check pipe supports: Secure any loose pipes with proper hangers or clamps to prevent movement.
  • Slow down closing valves: If you have adjustable zone valves, set them to close more slowly if possible.
  • Verify expansion tank: Ensure the expansion tank is properly charged and connected; a failed tank can worsen banging.

When to call a professional: Persistent water hammer may require installation of water hammer arrestors or system balancing by a technician.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Zone Valve
Check Price on Amazon

We may earn a commission from links on this page.